MICROLIFE MISUR PRESS B3
980143236
4719003342234
Out-of-Stock
€132.16
€132.16
€159.90
-€27.74
€132.16
microlife
Pressure Meter with Atrial Fibrillation Detection
Description
Clinically tested arterial pressure meter. AFIBsens reliably detects Atrial Fibrillation (FA) during pressure measurement in mode MAM (3 measurements with 1 click). Equipped with Gentle+ technology that ensures a more comfortable measurement with inflating and swelling of the most delicate bracelet. An integrated system for pressure control in the bracelet reduces arm constriction. The accuracy of this pressure gauge has been clinically tested according to the BHS (British Hypertension Society) protocol by achieving the highest level of A/A rating. Validated and also recommended for "difficult" patients such as children (over 12 years), diabetics, dialysis and/or patients with terminal phase kidney disease (ESRD), pregnant women and/or preeclampsia (gestosi), elderly and obese.
Cod. 10716
Clinically tested arterial pressure meter. AFIBsens reliably detects Atrial Fibrillation (FA) during pressure measurement in mode MAM (3 measurements with 1 click). Equipped with Gentle+ technology that ensures a more comfortable measurement with inflating and swelling of the most delicate bracelet. An integrated system for pressure control in the bracelet reduces arm constriction. The accuracy of this pressure gauge has been clinically tested according to the BHS (British Hypertension Society) protocol by achieving the highest level of A/A rating. Validated and also recommended for "difficult" patients such as children (over 12 years), diabetics, dialysis and/or patients with terminal phase kidney disease (ESRD), pregnant women and/or preeclampsia (gestosi), elderly and obese.
Technical specifications | |
---|---|
Operating temperature: | 10-40°C/50-104°F 15-95 % maximum relative humidity |
Storage temperature: | -20-+55°C /-4 - +131°F 15-95 % maximum relative humidity |
Weight: | 402 g (including batteries) |
Size: | 138 x 94,5 x 62,5 mm |
Measuring procedure: | oscillometric, corresponding to the method of Korotkoff: phase I systolic, phase V diastolic |
Measurement range: | 20-280 mmHg-pressure arteriosa 40-200 beats per minute-pulsations |
Armband Inflator Pressure Range: | 0-299 mm |
Resolution: | 1 mm |
Static pressure accuracy: | pressure within ± 3 mmHg |
Pulsation accuracy: | ± 5 % of the bed value |
Power supply: | 4 x 1.5 Volt alkaline batteries; type AA dC transformer 6V, 600 mA (optional) |
Battery life: | approssim. 920 measurements (using new batteries) |
IP class: | IP20 |
Reference to standards: | EN 1060-1 /-3 /-4; IEC 60601-1; IEC 60601-1-2 (EMC); IEC 60601-1-11 |
Product life expectancy in use: | Device: 5 years or 10,000 measurements Accessories: 2 years |