THE TEST CHEMICAL SHALL BE USED IN THE...

THE TEST CHEMICAL SHALL BE USED IN THE MANUFACTURE OF THE TEST CHEMICAL

926444706
8024151399693
1 Item
Last items in stock
€6.47 €10.90 -€4.43

€6.47
Medical devices - medical devices Sensinitryl glove s/polvere s

 

Sensintryl

Nitrile gloves without dust

Medical gloves, for examination, disposable, not sterile in nitrile, without dust. Disposable. Class I according to Annex IX of Directive 2007/47/EC, as an invasive device for temporary use in relation to body orifices.
Testing glove, non sterile polyvalent disposable in nitrile. Ambidestro con polsino salva tearo. Without dust. Microruvida surface that guarantees maximum sensitivity and optimized grip capacity. Without natural rubber latex, it eliminates the risk of allergic reactions of type I and type IV related to the presence of hydro-soluble proteins and chemical residues. Resistant to oils and fats in general, oil, benzines and various solvents on an alcoholic and ketone basis. High ergonomics that allows prolonged use without fatigue; Made of opacity blue color with anti-fatigue color shades. The exceptional elasticity and sensitivity make them an excellent alternative to the traditional latex glove.

Use
Examination, exploration, therapy, diagnostics. Research laboratories. Chemical and pharmaceutical industries. Mechanical workshops and carriages. Food processing.

Components
Nitrile (Nipol LX550L NBR); sulphur (S); zinc oxide (ZnO); titanium oxide (TiO2); pigment antifoam agents; antiager/antioxidant; potassium hydroxide (KOH).

Biocompatibility
Primary Irritation Test on Rabbits (ISO 10993-10) with non-irritating outcome Cutanea Awareness test on Guinea pigs (ISO 10993-10) with negative outcome.

Viral penetration
Result extracted from the test report according to ASTM F 1671: “3 samples were tested. The 3 samples passed the test. No viral penetration has been observed.”.

AQL for micro-holes
AQL 1.5 for inspection according to UNI EN 455 Part 1 and sampling plan according to ISO 2859 (General Inspection Level G1).
AQL
AQL for visible defects
AQL 2.5 for major defects – AQL 4.0 for minor defects ISO 2859 inspection level G1.

AQL for size
AQL 4.0 ISO 2859 inspection level S-2 sampling plan.

Chemical additive residues
TMTD, MBT, ZMBT, ZDEC, ZDMC, ZPMC, ZDBC, BHT, BHA : absent or below the detectability threshold.

Conservation - Disposal
Five years from the date of production.
The device, at the end of its use, must be treated in accordance with the applicable regulations in relation to the scope in which it was used.

Warnings
The glove must be worn before the start of the operation. The choice of the glove must be made by knowing the working activity and the processing process performed by the operator, taking into account the working conditions and risks connessi.Guanto disposable to use in chemically and mechanically non-aggressive activities; Keep the package for more information and ensure traceability; Store the gloves in their original packaging in a cool and dry place. Avoid direct exposure to sunlight, ozone and heat sources; Always carry out a preliminary test in the actual conditions of use; Do not use gloves in contact with the chemical tested for periods higher than those related to the performance level ( 0 10 min. ; 2 > 30 min. ; > 60 min. ; > 120 min. ; 5 > 240 min. ; > 480 min. ; Wear gloves with dry and clean hands. The product does not need safety cards.

Physical property
  
XS
S
MM
L
XL
Weight
2.5 +/- 0.3 gr
3,0 +/- 0.3 gr
3.5 +/- 0.3 gr
4,0 +/- 0.3 gr
4.5 0.3 gr
Length
mm. 245 +/- 5 mm
mm. 245 +/- 5 mm
mm. 245 +/- 5 mm
mm. 245 +/- 5 mm
mm. 245 +/- 5 mm
Width
mm 80 +/- 10 mm
mm 95 +/- 10 mm
mm 110 +/- 10 mm
> = 110 mm
Dust Thickness
0.05 +/- 0.01 mm (single wall)
0.10 +/- 0.02 mm (double wall)
0.05 +/- 0.01 mm (single wall)
0.10 +/- 0.02 mm (double wall)
0.05 +/- 0.01 mm (single wall)
0.10 +/- 0.02 mm (double wall)
0.05 +/- 0.01 mm (single wall)
0.10 +/- 0.02 mm (double wall)
0.05 +/- 0.01 mm (single wall)
0.10 +/- 0.02 mm (double wall)
Palm Thickness
0.07 +/- 0.01 mm (single wall)
0.14 +/- 0.02 mm (double wall)
0.07 +/- 0.01 mm (single wall)
0.14 +/- 0.02 mm (double wall)
0.07 +/- 0.01 mm (single wall)
0.14 +/- 0.02 mm (double wall)
0.07 +/- 0.01 mm (single wall)
0.14 +/- 0.02 mm (double wall)
0.07 +/- 0.01 mm (single wall)
0.14 +/- 0.02 mm (double wall)
Thickness
0.07 +/- 0.01 mm (single wall)
0.14 +/- 0.02 mm (double wall)
0.07 +/- 0.01 mm (single wall)
0.14 +/- 0.02 mm (double wall)
0.07 +/- 0.01 mm (single wall)
0.14 +/- 0.02 mm (double wall)
0.07 +/- 0.01 mm (single wall)
0.14 +/- 0.02 mm (double wall)
0.07 +/- 0.01 mm (single wall)
0.14 +/- 0.02 mm (double wall)
N.B. the indication "single wall" or "double wall" refers to the measurement of the thickness performed alternately by individually measuring the glove membrane on one side of the hand (single wall) or by measuring the entire thickness of the glove (double wall).

Permeation levels
  
Protection level
Dietilamina (Cod. G)
Class 2
Sodium hydroxide by 40% (Cod. K)
Class 3
Sulphuric acid at 96% (Cod. L)
Class 2
Ethyl Acetate
Class 2
Acetylsalicylic acid
Class 4
Dimethylformamide
Class 2
Glutaraldeide 3 %
Class 3
Sekumatic
Class 4
Iosciamina Hydrochloride
Class 4
Isopropanol
Class 2
n. Esano
Class 2
10% Nitric Acid
Class 2
Nitric acid at 65%
Class 2
Formaldehyde to 4 %
Class 3
Amuchina
Class 5
Citrosil
Class 5

Format
Available in different sizes. Pack of 100 pieces.

Cod. 39973P / 39969P / 3970P / 39971P / 39972P

Deductible product
Yes
926444706
1 Item
New
No reviews

Potrebbe interessarti

Gli altri clienti hanno ordinato

Product added to wishlist