ESPACE NEO DISTANCE C/MAS AR

ESPACE NEO DISTANCE C/MAS AR

905727374
8015662713528
69 Items
€27.43 €38.50 -€11.07

€27.43
Aerosol - aerosol devices The espace neo detached c/mas ar

 

The espace

Description
Spacer room for predosed sprays.
The use of the spacer room is recommended by the International Guidelines for the proper treatment of asthma.
The spacer is recommended for the proper deposition of the drug in the lower airways, since the direct use of the inhaler, given the high speed of the outgoing drug, would cause the concentration of nebulized medicine in gold-pharynx.
The espace helps to limit the side effects of oropharyngeal deposition of the drug and facilitates coordination between the inspiratory act and dispensing with the predose spray.
Espace simplifies therapy and provides more effective treatment with all predosed inhalers due to adequate spread of the nebulized drug in the lower airways.
Conical shape whose flow dynamic makes available a greater fraction of the drug increasing the deposition in the low airways.
Ideal volume: Espace reduces the reaggregation of the nebulized drug particles thanks to the volumetrics specifically studied.
Lamellar Fund: The espace is equipped with variable opening blades that adapt to the force of the patient’s inspiratory act, facilitating therapy.
Anatomical and ergonomic mask that facilitates compliance with even the smallest. Excellent adherence with minimal pressure.
Valve system: the colored valve is a valid help for the visual control of respiratory acts. The movement is clearly evident: it allows proper coordination between the dispensing of the drug and the intake and allows to count the respiratory acts.
Base with universal graft for all MDI predose sprays (Metered Dose Inhalers). All models are sterilisable at 121°C. Low electrostatic charges. Fabric bag for better hygiene and safer transport. Durable and robust materials.
Latex-free.

Mode of use
1 - before use, carefully examine the product by checking that it is assembled correctly and that there are no foreign bodies or missing components. Remove each foreign body before use;
2 - before use, read the instructions provided with MDI. Remove the lid from MDI;
3 - introduce the MDI into the bottom;
4 - put your mouth in your mouth and keep it in your lips;
5 – press the MDI and inhale slowly through the mouth. Keep the mouthpiece in the mouth with the lips well adhered for at least 5 respiratory acts after pressing the inhaler. During the intake from the openings on the bottom enters air that facilitates the inhalation of the nebulized. The exhale air comes out through the exhalation valve;
6 - wait 30 seconds before administering another dose of medication (respect steps 4-5), or as indicated by your doctor. Administer only one drug puff at a time and follow the doctor's dosage instructions.

Cleaning
if the device is always used by the same person to clean it as indicated. If the device is used by several people, after each use, in addition to cleaning, a sterilization in autoclave at 121°C for 15 minutes. The device can be sterilized without compromising its functional characteristics up to 20 times, then it is necessary to replace it. If considered appropriate, for a thorough cleaning, it is possible to boil the device or to wash it in the dishwasher.
A - the product should be cleaned following the following instructions before first use and then at least once a week: remove bottom and mask;
B - leave the parts to bath for 15 minutes in warm water with neutral detergent to disinfecting action. Gently act;
C - rinse in clean water;
D - shake to eliminate excess water as shown. Do not use dry cloth to dry the parts of the device. Make sure the parts are dry before reassembling them;
And - put the bottom and mask in place when the parts are completely dry and ready for use. Hundred the alignment arrow present on the back component with the alignment socket present on the body as shown.

Warnings
Replace the product in case there is a damaged component. Some components for their size could be swallowed by children. Do not leave these components unattended. The presence of an adult is always necessary. Do not disassemble the product as indicated in the cleaning instructions. If you have any doubts about the use of the product, consult your doctor or pharmacist. Clean the product only as indicated in these instructions to ensure the effectiveness of operation.

Conservation
When not used, store the product in a clean container.
Replace the product after 24 months of continuous use.

Format
- Yellow background: mask for children 2-6 years;
- orange background: mask for children 0-2 years;
- magenta bottom: adult mask.

Cod. 471351 ( yellow background)
471352 (orange background)
471386 ( magenta background)

Deductible product
Yes